Hydraulic Shut-Off Valve in High Pressure and Emergency, Flange Ends, PN 10 Bar
PRODUCT INTRODUCTION
1. Description
900X Pressure Relief / Pressure Sustaining & Shut Off Valve for Fire Protectionis used in the living and fire-fighting emergent water supply system. It supplies living water in the normal conditions.And in case of a fire, close automatically the living water and open the fire-fighting one to make it enough, and when the fire-fighting water stops and the pressure is reduced, resets the living water automatically.
Thus making the system no need to set a separate fire-fighting water supply pipeline, this saves both engineering construction cost and daily water quantity used greatly. It features by the sensitive control, safety, reliability, simple debugging and long duration.
This is a kind of valve used to balance the differential pressure in air conditioner system. This kind of valve improves the systems using percentage and maintaining precise and stable differential pressure and at most degree low eliminate noise in the system and damage to the system due to over pressure differential.
This valves most advantage is that its without actuator, compared to with other balance valve, and it can balance the system by mediums own differential pressure and thus saves energy and installation space.
Nominal Pressure (MPa) | Shell Test (MPa) | Sealing Test (MPa) | Fluids | Fluids Temp (°C) |
1.0 | 1.5 | 1.1 | Water | 0-80 |
1.6 | 2.4 | 1.76 | ||
2.5 | 3.75 | 2.75 |
4. Hydraulic Control Valve Outsize Drawing
DNmm | 20 | 25 | 32 | 40 | 50 | 65 | 80 | 100 | 125 | 150 | 200 | 250 | 300 | 350 | 400 | 450 | 500 | 600 | 700 | 800 | |
L | 180 | 180 | 180 | 203 | 203 | 235 | 280 | 360 | 400 | 455 | 585 | 650 | 800 | 860 | 915 | 980 | 1075 | 1230 | 1300 | 1450 | |
PN10 | D | 105 | 115 | 135 | 145 | 160 | 180 | 195 | 215 | 245 | 280 | 335 | 390 | 440 | 500 | 565 | 615 | 670 | 780 | 895 | 1010 |
D1 | 75 | 85 | 100 | 110 | 125 | 145 | 160 | 180 | 210 | 240 | 295 | 350 | 400 | 460 | 515 | 565 | 620 | 725 | 840 | 950 | |
PN16 | D | 105 | 115 | 135 | 145 | 160 | 180 | 195 | 215 | 245 | 280 | 335 | 405 | 460 | 520 | 580 | 640 | 705 | 840 | 910 | 1020 |
D1 | 75 | 85 | 100 | 110 | 125 | 145 | 160 | 180 | 210 | 240 | 295 | 355 | 410 | 470 | 525 | 585 | 650 | 770 | 840 | 950 | |
PN25 | D | 105 | 110 | 135 | 145 | 160 | 180 | 195 | 230 | 270 | 300 | 360 | 425 | 485 | 550 | 610 | 660 | 730 | 840 | 955 | 1070 |
D1 | 75 | 85 | 100 | 110 | 125 | 145 | 160 | 190 | 220 | 250 | 310 | 370 | 430 | 490 | 550 | 600 | 660 | 770 | 875 | 990 | |
H | 342 | 342 | 342 | 395 | 395 | 405 | 430 | 510 | 560 | 585 | 675 | 730 | 760 | 840 | 910 | 1070 | 1135 | 1270 | 1460 | 1640 | |
H1 | 247 | 247 | 247 | 278 | 278 | 298 | 313 | 350 | 365 | 420 | 450 | 470 | 490 | 526 | 570 | 610 | 665 | 725 | 865 | 975 |
Note: Either elastic seat ring sealed gate valve or butterfly valve can be selected in the schematic of installation. Recommend to select the butterfly valve in case of DN350.
If you require other sizes and valve design standards, please send email to angela@tjfmcn.com to get the drawing.
5. Hydraulic Control Valve Packing with Plywood
Please feel free to contact with us at angela@tjfmcn.com or filling up an enquiry form instructed at the bottom.
You will get an effective response within 24 hours from TongJiang Team.
Miss Angela
Mobile: +86 13588429004(Whatsapp)
Skype: angelazhuo1
E-mail: angela@tjfmcn.com
Tel No: +86 571 86991717
Official Website: www.zjtjvalve.com